QCLINUX: arm64: dts: qcom: Update Purwa camera sensor regulator voltage - #1073
Merged
Salendarsingh Gaud (sgaud-quic) merged 1 commit intoSep 10, 2026
Conversation
…M/L6M Correct the regulator-min-microvolt for L4M and L6M from 1808000 to 1800000. Signed-off-by: Shubam Mishra <shubamm@qti.qualcomm.com>
shubammm (shubammm)
requested review from
a team,
Amit Kucheria (idlethread),
knaveen-qc and
Tingwei Zhang (quic-tingweiz)
September 10, 2026 06:43
|
Merge Check Failed: No CR Numbers Found Error: No Change Request numbers were found. Please add Change Request numbers to your pull request description in the format CRs-Fixed: 12345 or link GitHub issues that are associated with Change Requests. |
Komal Bajaj (Komal-Bajaj)
approved these changes
Sep 10, 2026
Author
|
qli-2.1 pull-request freeze |
Test Matrix
|
Salendarsingh Gaud (sgaud-quic)
merged commit Sep 10, 2026
cf806dc
into
qualcomm-linux:qcom-6.18.y
6 of 8 checks passed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Update rgltr-min-voltage for cam-sensor1 (og0a1b) and cam-sensor4
(imx688) on the Purwa board from 1808000 to 1800000 to match the
corrected vreg_l4m_1p8 / vreg_l6m_1p8 LDO regulator-min-microvolt
value.
CRs-Fixed: 4665973