Indoor temperature, pressure and humidity from a BME280 on a Raspberry Pi, alongside outdoor readings from the Met Office. Published to Home Assistant over MQTT and/or logged to MongoDB.
- Reads a BME280 over I2C at a set interval (default every 10 minutes).
- Fetches outdoor observations from the nearest Met Office weather station via the Weather DataHub Land Observations API (free plan). It polls at most once an hour by default and stays well inside the 360 calls/day limit.
- Publishes to MQTT for Home Assistant, and/or stores to MongoDB for history and charts (MongoDB Atlas and Charts both work on the free tier).
- Runs without hardware: a fake sensor lets you try it, or develop on it, on Windows or macOS.
- Every output can be switched on or off in the config. The config is validated at start-up, and secrets are never logged.
Example chart: BME280 readings in MongoDB Atlas, charted with MongoDB Charts.

Needs Python 3.11 or later.
git clone https://github.com/ajyounguk/bme280-sensor-logger
cd bme280-sensor-logger
python -m venv .venv
# Windows: .venv\Scripts\activate Linux/macOS: source .venv/bin/activate
pip install -r requirements.txt
python main.py --config config/config-fake.jsonconfig/config-fake.json uses "sensor": {"type": "fake"} and turns off MQTT, MongoDB and the Met Office, so it
just logs plausible readings every 10 seconds:
[INFO 2026-11-16 13:28:48] - bme280-sensor-logger starting...
[INFO 2026-11-16 13:28:48] - Sensor: fake (I2C port 1, address 0x76)
[INFO 2026-11-16 13:28:48] - BME280 - Temperature: 21.05 °C, Pressure: 1012.51 hPa, Humidity: 45.88 %
To try MQTT or MongoDB without a sensor, copy config-example.json as below and set sensor.type to "fake".
- Enable I2C:
sudo raspi-config, then Interface Options, I2C, Enable. - Install the tools and clone the repo:
sudo apt update && sudo apt install -y git python3-venv i2c-tools git clone https://github.com/ajyounguk/bme280-sensor-logger cd bme280-sensor-logger python3 -m venv .venv && source .venv/bin/activate pip install -r requirements.txt
- Check that the sensor is visible:
i2cdetect -y 1should show76or77. Older 256 MB Pis use bus0. If it doesn't show, check the wiring. This guide helps. - Create your config (see below), then do a single test run:
python main.py --once
cp config/config-example.json config/config.jsonconfig/config.json is git-ignored. It's where your API key and passwords go, so keep it out of anything you share.
The app refuses to start while any YOUR_... placeholders are left in, and tells you what's wrong.
{
"app": { "readingIntervalSeconds": 600, "deviceName": "lounge_pi", "logLevel": "INFO" },
"sensor": { "type": "bme280", "i2c_port": 1, "bme280_address": "0x76" },
"metoffice": { "enabled": true, "APIKey": "YOUR_DATAHUB_LAND_OBSERVATIONS_API_KEY",
"latitude": 51.5, "longitude": -0.12, "pollIntervalSeconds": 3600 },
"mongo": { "enabled": true, "uri": "mongodb+srv://MONGO_USERNAME:MONGO_PASSWORD@cluster0.example.mongodb.net/?retryWrites=true&w=majority",
"dbName": "YOUR_DB_NAME", "collection": "house_temperature_readings",
"sensorSource": "lounge", "metofficeSource": "outside" },
"mqtt": { "enabled": true, "broker": "homeassistant.local", "port": 1883,
"mqttUsername": "YOUR_MQTT_USERNAME", "mqttPassword": "YOUR_MQTT_PASSWORD",
"sensorTopic": "homeassistant/bme280_lounge", "metofficeTopic": "homeassistant/metoffice" }
}| Key | Meaning |
|---|---|
app.readingIntervalSeconds |
Seconds between sensor readings (5 to 86400) |
app.deviceName |
Tags MQTT messages and MongoDB documents |
app.logLevel |
DEBUG, INFO (default), WARNING or ERROR |
sensor.type |
bme280 (default), or fake for no hardware |
sensor.i2c_port |
I2C bus, usually 1 |
sensor.bme280_address |
"0x76" or "0x77" |
metoffice.enabled |
Fetch outdoor observations |
metoffice.APIKey |
Your DataHub Land Observations key (see below) |
metoffice.latitude / longitude |
Your location. The nearest station is looked up once at start-up |
metoffice.geohash |
Optional: a station geohash, used instead of lat/lon |
metoffice.pollIntervalSeconds |
How often to call the API. Default 3600, minimum 300 |
mongo.enabled, uri, dbName, collection |
MongoDB connection and target |
mongo.sensorSource / metofficeSource |
source label on sensor and Met Office readings. Also used in MQTT messages |
mqtt.enabled, broker, port |
MQTT broker (default port 1883) |
mqtt.mqttUsername / mqttPassword |
Broker credentials. Leave both empty for an anonymous broker |
mqtt.sensorTopic / metofficeTopic |
Topics for each kind of reading |
The Met Office retired DataPoint in 2025. Outdoor readings now come from Weather DataHub's Land Observations API: hourly measurements from about 150 UK stations.
- Register at datahub.metoffice.gov.uk.
- Subscribe to Land Observations on the free plan (360 calls/day). It's a separate subscription from Site Specific forecasts, and its key is different.
- Put the key in
metoffice.APIKeyinconfig/config.json.
Observations update hourly, so the default pollIntervalSeconds of 3600 is plenty. The app also keeps its own
daily call budget. If the API ever returns "quota exceeded", it pauses Met Office calls until midnight UTC, when
the quota resets. The sensor keeps running either way.
Upgrading from v1:
metoffice.locationIDwas a DataPoint ID. Replace it withlatitudeandlongitude, and use a DataHub key. The app tells you if an old config is still in place. Met Office wind is now in m/s; DataPoint reported mph.
python main.py # run forever with config/config.json
python main.py --once # one reading, then exit
python main.py --config other.json # another config filepm2 keeps the app running and starts it on boot. It handles Python apps fine.
sudo apt install -y nodejs npm && sudo npm install -g pm2
pm2 startup # then run the command it prints
pm2 start main.py --name bme280 --interpreter .venv/bin/python
pm2 save
pm2 logs bme280 # view logs; also: pm2 status / restart bme280 / stop bme280Run an MQTT broker (the Mosquitto add-on is the easy route) with a dedicated user for this app. Then add sensors
to configuration.yaml:
mqtt:
sensor:
- name: "BME280 Temperature"
state_topic: "homeassistant/bme280_lounge"
unit_of_measurement: "°C"
device_class: temperature
value_template: "{{ value_json.temperature }}"
- name: "BME280 Pressure"
state_topic: "homeassistant/bme280_lounge"
unit_of_measurement: "hPa"
device_class: pressure
value_template: "{{ value_json.pressure }}"
- name: "BME280 Humidity"
state_topic: "homeassistant/bme280_lounge"
unit_of_measurement: "%"
device_class: humidity
value_template: "{{ value_json.humidity }}"
- name: "Met Office Temperature"
state_topic: "homeassistant/metoffice"
unit_of_measurement: "°C"
device_class: temperature
value_template: "{{ value_json.temperature }}"
- name: "Met Office Pressure"
state_topic: "homeassistant/metoffice"
unit_of_measurement: "hPa"
device_class: pressure
value_template: "{{ value_json.pressure }}"
- name: "Met Office Humidity"
state_topic: "homeassistant/metoffice"
unit_of_measurement: "%"
device_class: humidity
value_template: "{{ value_json.humidity }}"
- name: "Met Office Wind Speed"
state_topic: "homeassistant/metoffice"
unit_of_measurement: "m/s"
device_class: wind_speed
value_template: "{{ value_json.wind }}"To watch the raw messages, go to Settings, Devices & services, MQTT, Configure, and listen on your topic.
Message payloads:
// sensorTopic
{"source": "lounge", "temperature": 21.05, "pressure": 1012.51, "humidity": 45.88, "wind": null}
// metofficeTopic (re-sent every cycle with the latest observation)
{"source": "outside", "temperature": 9.13, "humidity": 85.0, "pressure": 1025.0, "wind": 1.4,
"observedAt": "2026-11-16T10:00:00Z", "deviceName": "lounge_pi"}Each reading becomes one document:
{ "source": "lounge", "timestamp": "2026-11-16T10:12:00Z", "temperature": 21.05, "pressure": 1012.51,
"humidity": 45.88, "wind": null, "deviceName": "lounge_pi" }Met Office documents also carry observedAt, the station's observation time. Each observation is stored once,
even when several devices share a collection with the same metofficeSource. Visualise the data with
MongoDB Charts.
pip install -r requirements-dev.txt
python -m pytest # all tests; the sensor, MQTT, MongoDB and Met Office are faked
ruff check . && ruff format .- No network, broker, database or hardware is needed. The Met Office tests use recorded-style fixtures in
tests/fixtures/. tests/test_hardware.pyreads a real BME280. It's skipped unless it runs on Linux with/dev/i2c-1present. On the Pi:pytest -m hardware -v. SetBME280_I2C_PORT/BME280_ADDRESSif yours differ.- CI runs ruff and pytest on Ubuntu and Windows (Python 3.11 and 3.13). Dependabot keeps the pinned versions fresh.
- Code layout and design decisions: docs/design.md. API notes: docs/metoffice-datahub.md.
- Publish in Home Assistant MQTT auto-discovery format, so the YAML above isn't needed.
MIT. See LICENSE.